A system for all applications! Threads of 20 to 30 mm and the most varied plate sizes with 6 to 15 mm material thickness - we have the perfect solution for any application. Lift-off and lateral impacts can be counteracted with a straight screw connection into the cross-grained wood using fully-threaded 10 x 120 mm wood screws (with European Technical Approval) or a strut or lateral latches. Of course, post bases of the right/left-threaded system are still height-adjustable when mounted and under heavy load. The use of additional lock nuts increases the rigidity of the connection.
PURPOSE
Timber Structure Engineering
Post Base Support
Adjustable Heights
SUITABILITY
Glue Laminated Timber GLT
Solid Timber
SUMMARY
Item No. 10529.7098
Upper Plate W x H (mm) Ø 96 x 8
Bottom Plate W x D x H (mm) 110x110x6
Thread M 24 bottom 90
Installation height mm 175 - 235
Hole Ø 13 mm bottom 4
Hole Ø 10.5 mm top 4
TECHNICAL Grade C24
F 1,Rk (compression) = 41.3 kN compressive capacity in the direction of the wooden column
F 1,Rk (tension) 120mm = 30.0 kN tension capacity in the direction of the timber column
F 1,Rk (tension) 160mm = 50.0 kN tension capacity in the direction of the timber column
F 2/3, Rk Hinged = 5.6 kN Horizontal load-bearing capacity in the direction of the longer side of the base plate
F 2/3, Rk Clamped = 12.5 kN Horizontal load-bearing capacity in the direction of the longer side of the base plate
F 4/5,Rk Hinged = 5.6 kN* Horizontal load-bearing capacity in the direction of the shorter side of the base plate
F 4/5,Rk Clamped = 12.5 kN* Horizontal load-bearing capacity in the direction of the shorter side of the base plate
By using screws Ø 10 x 160 the character lift value can be increased to 50.0 kN.
INSTALLATION INSTRUCTION
The pre-assembly of the post base is already performed in the workshop and provides for a quick and comfortable work on the building site. The innovative Pitzl‘s plug-in system can be smoothly and fast locked and unlocked. The upper plate can with only few gestures be separated from the rest of the post base.
1. Turn the fastening anticlockwise up to stop.
2. Press fastening down.
3. Press fastening further anticlockwise.
DISCLAIMER
The number and arrangement of the post supports as well as the installation and assembly must be taken from the specifications according to ETA-10/0413 and observed. In principle, the requirements of DIN EN 1995 apply.
Accessories
Washer-head screw 10 x 120 mm
Washer-head screw 10 x 160 mm